Building dynamics, protections against vibrations and earthquake influence

  • Estimations, planning and expert opinions for protection of buildings and people against influences of vibrations due to road and railway traffic, engines and earthquake
  • Steel chimney Munich-Gaisberg – vibration control
  • Expert advise for bell towers of churches “Zu den hl. Engeln”, “Klosterkirche Forstinning” caused by vibrations due to bell ringing
  • Munich, Rosenheimer Str. 133 – giving expert advise and planning of damping measures for protection against vibrations emitted by a subway tunnel directly beneath the building
  • Cable-tightened pylon Kreuzberg / Rhoen – expertise for vibration control due to wind effects
  • Earthquake analysis of dam wall Ernstbachtal near Wiesbaden
  • Munich-Frankfurter Ring 211-217, design of 8 story administration building completely supported through steel springs for vibration control (REF 02)
  • Expert opinion for a housing project in Munich-Feldmoching influenced by vibrations from a nearby railway
  • Day-nursery and youth center Munich – Neuherbergstrasse, vibration control for a building directly above underground railway (estimation of vibrations, designing of structures, building inspection and measurement during the construction progress, REF 17)
  • Inspection and expert opinion for existing facilities of the German embassy in Indonesia concerning influences of earthquakes
  • Inspection of the steel construction and internal parts for the cold box Yanbu-L for Linde AG concerning influences of earthquakes (REF 18)
  • structural design for entrance building for the camp Marmal, Mazar é Sharif, Afghanistan concerning influences of earthquakes and explosions
  • Measurement of vibrations with MEDA system

Downloads

REF 02: Frankfurter-Ring - 188 kB
REF 17: nursery_school-and-youth_club - 659 kB